The HP NS2000 family of servers provides you with all the benefits of the NonStop software suite, including software fault tolerance and fault isolation, dynamic workload balancing, linear scalability, application virtualization and cluster programming transparency. The servers can be configured with two or four dual-core processors in a pre-assembled, integrated rack-mount configuration. Multiple servers can be connected together using Expand-over IP.
The three models include:
- NS2000 server is an AC-powered server packaged in a standard commercial rack
- NS2000T is packaged in a commercial rack and is DC-powered (-48V)
- NS2000ST is packaged in an extra sturdy seismic rack and is also DC-powered (-48V)
|
|
|
 |
 |
 |
 |
 |
| Specifications |
NS2000, NS2000T and NS2000ST |
| Altitude |
Operating: 10,000 ft (3,000 m) maximum
Nonoperating: 40,000 ft (12,000 m) maximum |
| Temperature |
Operating: 40° to 100°F (5° to 35°C)
Nonoperating: -40° to +150°F (-40° to +66°C)
Maximum rate of temperature change: 36°F (20°C) per hour |
| Humidity |
Operating: 10% to 85% relative noncondensing maximum
Nonoperating: 95% maximum at 150°F (66°C) |
| Dimensions |
78.7 x 46.65 x 24 in. (199.9 x 118.5 x 60.96 cm) (42U)
68.6 x 46.65 x 24 in. (174.2 x 118.5 x 60.96 cm) (36U) |
| Weight |
1,110 lb. (505 kg) |
| Power supply |
Typical power dissipation: 2,200 VA
Input current: 14 A @ 200 VAC
AC input power: 200–240 V, 50–60 Hz
NS2000T, NS2000ST
Nominal value: -48 VDC
Operating range: -40 to -72 VDC |
| Safety |
Compliant with UL 60950-1/CSA C22.2 NO. 60950-1-03, and EN 60950 |
| Electromagnetic interference |
Complies with FCC rules and regulations, Part 15, as a Class A Digital Device; manufacturer’s declaration to EN 55022 Level A |
| Power line LF emissions |